Thermal Expansion Tank Tie-In in Annapolis Junction, MD

Install a backflow preventer on a home's main line and you have created a closed system. When the water heater runs, heated water expands and has nowhere to go. Pressure climbs until the temperature and pressure relief valve on the heater, set at 150 psi, starts to weep.

A thermal expansion tank fixes that. It is a small steel tank with an air bladder, tied into the cold supply near the heater. The bladder absorbs the expansion.

The detail people skip is the air charge. The tank has to be pre-charged to match your static water pressure, checked with a tire gauge before it goes on. A tank left at the factory 40 psi on a 70 psi system does very little.

Sizing depends on heater capacity and water pressure. A 40 or 50 gallon heater usually takes a 2 gallon tank.

Grizzly Backflow & Plumbing connects Annapolis Junction, MD homeowners with plumbers who tie in expansion tanks as part of backflow prevention work. Call (833) 990-5874.

How it works

Four steps to backflow testing in Annapolis Junction, MD

  1. 01

    Grab your notice

    Have the utility letter handy. It lists the device, serial number and due date.

  2. 02

    Talk it through

    Call (833) 990-5874. We go over the device type and the price before anything is booked.

  3. 03

    Test day

    A certified tester reads each check and the relief valve on a calibrated gauge.

  4. 04

    Report filed

    The report goes to your water utility, and you keep a copy for your records.

Coverage

Backflow Testing Services Across Annapolis Junction, MD

Backflow testing for the neighborhoods and ZIP codes around Annapolis Junction, MD.

ZIP codes we serve

20701

Backflow testing FAQs

Questions about backflow testing

Questions we hear most often about Thermal Expansion Tank Tie-In in Annapolis Junction, MD.

Talk to a person
Who is allowed to test my backflow device?
A tester who holds a backflow tester certification recognized by your state or your water utility. Many utilities keep an approved tester list and reject reports signed by anyone not on it.
How long does a backflow test take?
A residential PVB or double check test usually takes 20 to 30 minutes. Large commercial and fire line assemblies take longer.
What does a failed backflow test mean?
A check valve or the relief valve did not hold its required pressure differential. The device needs repair or replacement, then a retest before a passing report can be filed.
Can a backflow preventer freeze?
Yes. Trapped water expands and can crack the bronze body or blow out the bonnet. Insulated enclosures, heat cable or draining the device for winter prevent it.
Can a backflow preventer be repaired instead of replaced?
Often it can. Rebuild kits with new discs, springs and seals are sold for most brands. Replacement makes more sense when the body is cracked or parts are no longer made.